66 1 Operation
1.1 Operation
Continuous probe firing
Probes can be dry-fired continuously to show data points that would
be acquired under the current light, focus, part alignment and other
current measurement conditions if the probe were actually fired. The
data points are shown in blue until the probe is fired to acquire points,
then the acquired points are shown momentarily in red.
To enable Continuous Fire:
Right-click the Live Video window to display the Window menu
Select Other>Continuous Fire
or
Click the Continuous Fire button on the VED toolbar
Continuous Fire enabled
Continuous probe firing is useful for setup and
troubleshooting activities, but requires substantial system
resources and should be avoided during routine use to
maintain high throughput.
Enable Continuous Fire from menu
Enable Continuous Fire from VED toolbar