June 2011 3 – 17
X25 Ethernet interface, RJ45 connection, 10BaseT
Maximum cable length: non-shielded: 100 m
shielded: 400 m
X26 Ethernet interface, BNC connection, 10Base2 (coaxial cable)
Maximum cable length: 180 m
RJ45 connection (female) 8-pin Assignment
1TX+
2TX
3REC+
4 Not assigned
5 Not assigned
6REC
7 Not assigned
8 Not assigned
BNC connection (female) Assignment
Inner conductor (core) Data (RXI, TXD)
Shield GND
Control model Ethernet connector
(option)
X25 X26
TNC 426.B x x
TNC 430.A x x
TNC 426M/430M x x