Heidenhain TNC 620 (34056x-04) Cycle programming Manual de usuario Pagina 382

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 468
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 381
Touch Probe Cycles: Automatic Workpiece Inspection
16.9 MEASURE INSIDE WIDTH (Cycle 425, DIN/ISO: G425, software
option 17)
16
382
TNC 620 | User's Manual Cycle Programming | 5/2013
Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (See "Tool
monitoring"). Input range 0 to 32767.9, alternatively
tool name with maximum of 16 characters
0: Monitoring inactive
>0: Tool number in the tool table TOOL.T
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP (touch probe table), and
is only effective when the datum is probed in the
touch probe axis. Input range 0 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Vista de pagina 381
1 2 ... 377 378 379 380 381 382 383 384 385 386 387 ... 467 468

Comentarios a estos manuales

Sin comentarios